Search Catalog
      GO   
 All Categories    Gas Cells - Short Path and Long Path for FTIR Gas Analysis
View Cart View RFQs Express Ordering  | Shipping 
 | Tax 
 | Terms
 Shopping Cart 0 Items
 Request for Quote 0 Items
All Categories > Gas Cells - Short Path and Long Path for FTIR Gas Analysis  
 

Gas Cells - Short Path and Long Path for FTIR Gas Analysis


Click on a Product to view details.

FTIR Gas Analysis Cells

Mercury™ Single Pass Short Path Length Stainless Steel Specialty Gas Cells

(12)

Short Path Gas cells for FTIR Gas Analysis, for concentrations of not less than 100 ppm. Cell utility for various ppm concentrations is dependent not only on path length, but also on the absorbance characteristics of the sample. Feel free to consult with us on these and any other issues concerning selection of an appropriate gas cell.
ICL's Gemini™ gas cell line begins with our Mercury™ short path length single pass gas cells constructed of electropolished 316 Stainless Steel, available in standard path lengths of 1cm, 2cm, 3cm, 5cm, 10cm and 15cm. Custom path length cells for a variety of applications are also available.
These robustly constructed gas cells are ideal for specialty FTIR gas analysis, because they are ...

Mars

Mars™ Long Path Gas Cells

(18)

For applications that demand high performance, durability, reliability, simplicity, dependability and serviceability, Gemini™ Mars™ gas cells are the solution. Mars™ long path cells address the most demanding gas sampling requirements of industrial and field deployed FTIR Gas Analysis and IR instrumentation with a robust series of metal bodied gas cells with electro-polished stainless steel or electro-less nickel plated aluminum bodies that outperform any gas cell on the market.
A key factor ensuring the durability and serviceability of each Mars™ cell is the use of stainless steel mirrors. These mirrors are extremely durable and they can be reconditioned many times at modest cost, thereby extending the ...

Gas Cells Venus

Venus™Glass Bodied Long Path Gas Cells

(10)

Venus™ cells are small to moderate volume long path gas cells designed for all purpose use in industrial and research applications. The cell design has improved significantly over the years with such advances as multilayer proprietary gold mirror coatings, improved purgeable transfer optics, and instrument specific base plate mountings. All Venus cells are fitted with Swagelok® 1/4" or 1/8" tube fittings to which valves, hose barbs or compression fittings can be attached. SS Swagelok® Valves are standard on the models listed.
Venus™ cell configurations include ICL's popular Ultra Mini Cell which measures 3" x 3" x 8" (3 meters fixed path length, 200cc volume), the Long Path Mini Cell (variable path length to 5 ...

Earth

Earth™ Glass Bodied Long Path Gas Cells

(8)

Gemini™ Earth™ glass bodied long path gas cells are, like Venus™ cells, classic Hanst cells, but with larger volumes and longer path lengths. Pathlengths range from 10 to 20 meters and volumes range from 2 to 8 liters.
All Earth™ cells feature SS Swagelok® valves, multilayer gold coated mirrors, borosilicate glass bodies, transfer optics and base plate configurations to fit most spectrophotometers, and black anodized aluminum hardware. Earth™ cells use 1/4" SS flow tubes and Swagelok® connections. All variable path length cells incorporate a laser alignment device with a 6 volt DC power supply for path length verification based on the number of passes made through the cell.
Several typical ...

Saturn Long Path Gas Cell

Saturn™ Long Path Gas Cells

(6)
Saturn Series Multi-Pass cells are Research-grade long path gas cells from 50 meters to 200 meters or more. Custom transfer optics and mounting hardware for center-focus or side port use on spectrometer systems are provided. An innovative advancement of the White optical configuration for long-long path length effectively triples the operational range of the instrument inside a moderate size cell volume. This provides path lengths in excess of 100 meters that can produce a strong IR signal throughput for trace level detection.

Saturn Series gas cells are ideal accessories for FTIR Gas Analysis and long pathlength studies of ambient ...

Search  Saturn™ Long Path Gas Cells - 6 Items

DemountableBetaGasCell

Demountable Beta Gas Cell 5 cm or 10cm

(7)
The demountable liquid Beta Gas Cell comes complete with a 10cm or 5cm Pyrex Cell body, cell mount, 2 Viton® O-rings or gaskets, 2 PTFE gaskets, and 2 septa, but without windows. (Windows and gaskets can be ordered separately). The window size is 25mm x 4mm. When assembled, the cell will be gas tight and operable at both reduced or positive pressures. Filling of the cell is conveniently handled with a gas tight syringe (ICL Part no. 0009-609).
G2GasCell

Model G-2 Gas Cell - 5cm or 10cm

(66)
The G-2 Gas Cell is for FTIR analysis of pure gases or gas mixtures in which component gases are present at concentrations of 5 percent or more. The G-2 Gas Cell has a fixed pathlength of either 5cm or 10cm. The windows of the cell are easy to remove for cleaning, making the G-2 ideal for working with wet or reactive gases that have a tendency to fog or attack the window material.
StainlessSteelGasCell

Model G-2SS 10cm Stainless Steel Gas Cell

(8)
The G-2SS stainless steel gas cell is useful for qualitative analysis of pure gases and mixtures where one or more of the constituent gases are present in concentrations of at least 5 percent. It can be used in situations that make use of a glass cell impractical, such as applications involving high pressure or gases that etch a glass cell body.
PTFEGasCell

G-3PTFE 10cm PTFE Gas Cell

(7)
All components of the G-3PTFE 10cm gas cell that contact the sample can be made entirely of PTFE, making the cell useful for any gas sample that might attack, or be contaminated by, glass or stainless steel gas cell components. The G-3PTFE is useful for analysis of pure gases and mixtures in which the constituent gases are present in concentrations of 5% or more.